POOL HEATERS
SWIMMING POOL HEATERS
Compact
Made of titanium/Nic-Tech or acid proof stainless steel/Incoloy 825. Supplied with thermostat, overheating cut out, a flow switch or pressure switch.
Aqua compact
Made of thermoplastic with heating element of Incoloy 825 or titanium. Supplied with thermostat, overheating cut out, flow switch.
Aqua spa
Made of thermoplastic with heating element of Incoloy 825. Ideal for spas and small pools. With thermostat, overheating cut out and flow switch.
Aqua HL digital
Made of thermoplastic with heating element of Incoloy 825 or titanium. Electric swimming pool heater features digital control and electronic thermostat.
Midi Heat
Highest quality materials. With digital or analogue temperature control, overheating cut out and flow switch. Effective heater for larger swimming pools.
We provide the most premium Swimming Pool Heaters.
These electric swimming pool heater are easy to connect to any existing electrical power-mains and it provides full power around the clock. The water from the swimming pool’s circulation flows through the heater and is heated by the heating element. The heaters are compact and can be installed in all types of pool or spa.
Pahlén electric heaters have at capacity range from 1,5 to 60kW. The smaller heaters within the range 1 to 3kW suit smaller pools and spas. Heaters in the range 3 to 18kw is for larger in ground and above ground pool while the lager heaters from 18 to 60kW is made for public facilities.
Pahlén manufactures electric heaters for spas, swimming pools and large adventure pools.
The materials used are AISI 316L acid-proof stainless steel, titanium and thermoplastic. All the electric heaters are designed for continuous flow with the lowest possible pressure drop. All Pahlén pool heaters are supplied with a thermostat as well as an overheating cutout. For extra security, a flow switch or pressure switch protects the heating element from damage if the flow to the heater is insufficient.
Triple safety!
– Aqua HL and MidiHeat are both equipped with dual contactors as an additional safety if one contactor should fail.
– The flow switch provides an additional safety if the water flow is too low.
– The overheating limit control provides an additional safety against overheating.
All these together give a triple safety that protects the product and the heating elements.
Theoretical heat calculation for your pool
Examples of calculation formulas for heating pools without any heat loss
Power is required to increase water temperature by △T degrees in a fixed time (t), assuming no heat loss.
Formula: P = 1.16 x △T x V
tTime taken to increase water temperature by △T degrees from a fixed power input, assuming no heat loss.
Formula: t = 1.16 x △T x V
P
P = Power in kW
t = Time in hour
△T = Temperature difference ℃
1.16 = Constant
V = Volume in m³
Example: Time is taken to heat 30 m³ of water from 5℃ to 25℃ with a 6kW heater, assuming no heat loss:
t = 1.16 x (25-5) x 30 = 116 hours
6